- Details
Use:
Monitoring the transient time and detecting the contact reliability of the connector and its component (wire harness) vibration test
Characteristic:
The completely independent parallel detection of the 10 loop has 10 independent displays, and the actual instantaneous break time window that exceeds the set value can be used to judge the fault location in time.
The transients of the measurable 0.1---99.9uS
A continuous inspection of the occurrence of a transient state
According to the technical standard of the tested products, the instant time of monitoring during the vibration, impact and collision test is set, and the monitoring and judging value is set up for monitoring instant breakup. (usually, the national military standard electrical connector test method stipulates: no more than 1uS instantaneous breakage is allowed during vibration, impact and collision test).
Technical parameter:
Model NM-10A NM-11A Set monitoring transient time
Not set 0.1~99.9S Number of monitoring loops 10 circuits in series 10 parallel circuits Transient display mode 1 display windows 10 display windows Monitoring transient time 0.1~99.9S Monitoring error ±0.1 S Monitoring voltage DC 5V Monitoring current 100mA